Portable gas detectors for oil and gas, petrochemical, utilities, tank cleaning and confined-space work in Saudi Arabia: 4- and 5-gas monitors from MSA ALTAIR, Honeywell BW and Industrial Scientific Ventis, the MultiRAE for up to six gases, pumped models for pre-entry testing, and single-gas H2S personal monitors including two-year maintenance-free BW Clip units. Quotes for single units or a fleet, delivered across the Kingdom.

Showing all 18 results

Top brands in Gas Detection

Buying for a project or a facility?Send us your list or drawings and we will quote quantities, delivery and product certificates.
Request a quote

Single-gas or multi-gas?

A single-gas detector is a personal monitor worn on the collar for one known hazard, most often hydrogen sulfide (H2S) on oil and gas sites. A multi-gas detector watches several hazards at once; the standard 4-gas set is oxygen (O2), combustible gases as a percentage of the lower explosive limit (LEL), carbon monoxide (CO) and H2S. If the hazard can change — confined spaces, tank cleaning, sewers, process plants — choose multi-gas.

NeedChooseModels here
Personal H2S protection all shiftSingle-gas H2SBW Clip H2S (2-year), Industrial Scientific T40 Rattler, MSA ALTAIR 2X
General 4-gas monitoring, worn by each workerDiffusion 4-gasMSA ALTAIR 4XR, BW Clip4 (2-year), BW MicroClip XL / X3, BW GasAlert Max, BW Quattro, Ventis MX4
Testing a confined space before entryPumped multi-gas with probe and hoseMSA ALTAIR 5X with pump and probe kit, BW Ultra (5-gas, pump), BW II with pump, Ventis MX4 with pump
Unusual gases or volatile organic compoundsConfigurable up to 6 sensorsMultiRAE series

Alarm points to know

Most detectors ship with alarm points close to these, and many sites keep them; your company standard may set others.

  • O2: low alarm 19.5 %, high alarm 23.5 % by volume.
  • Combustibles: 10 % LEL low, 20 % LEL high.
  • H2S: 10 ppm low, 15 ppm high.
  • CO: 35 ppm low, 200 ppm high.

Bump tests and calibration

  • Bump test before each day's use — a short exposure to test gas to prove every sensor and alarm responds. This is the industry practice and what most site permits ask for.
  • Full calibration at the interval set by the manufacturer and your site procedure, and always after a failed bump test.
  • Two-year disposable detectors such as the BW Clip and Clip4 need no battery or sensor changes, but still need bump testing.
  • Keep the records: inspectors and permit issuers ask for the last bump and calibration dates.

Brands in this category

  • MSA — ALTAIR 2X single-gas, ALTAIR 4XR and ALTAIR 5X multi-gas detectors, with pump, probe kits and filter covers.
  • Honeywell BW and RAE Systems — BW Clip, Clip4, MicroClip XL / X3, GasAlert Max, Quattro, BW Ultra and the MultiRAE series.
  • Industrial Scientific — Ventis MX4 multi-gas monitors and sensors, T40 Rattler single-gas.

Ordering for a crew or a project

Tell us the gases, the number of workers, whether you need pumped units for confined-space entry, and whether you need calibration gas and docking. We quote the detectors, spare sensors and accessories together. Use the quote request page, and see the PPE range and fire protection equipment for the rest of the safety kit.

Frequently asked questions

What is the difference between a 4-gas and a single-gas detector?

A single-gas detector monitors one hazard, usually H2S, and is worn as a personal alarm. A 4-gas detector monitors O2, combustible gases (LEL), CO and H2S together and is the standard choice where the atmosphere can change.

Do I need a pumped gas detector?

For testing a confined space before anyone enters, yes: a pump draws the sample through a hose from outside the space. For continuous personal monitoring while working, a diffusion detector worn on the body is enough.

How often should a gas detector be calibrated?

Bump test it before each day's use. Calibrate it at the interval the manufacturer and your site procedure set, and always after a failed bump test.

Do the BW Clip detectors need calibration?

They run for two years without battery or sensor changes, but they should still be bump tested before use to prove the sensor and alarms respond.

Can you supply spare sensors and accessories?

Yes, including sensors such as the Ventis MX4 oxygen sensor and accessories such as ALTAIR 5X filter covers. Send the model and part number with your quote request.